When Experience Matters!

Category: Interstitial & Secondary Containment Sensors

Showing all 11 results

  • Veeder Root Dual Point Hydrostatic Sensor

    $640.00

    The Dual-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Dual-Point Hydrostatic Reservoir Sensor is ideal for high groundwater areas, and can differentiate between a high level alarm condition and a low level alarm condition. If an inner-wall leak occurs, the brine seeps into the tank triggering a low-level alarm, if an outer wall leak occurs, fluid seeps into the interstice triggering a high-level alarm.

    Add to cart
  • Veeder Root Interstitial High Alcohol Sensor for Steel Tanks

    $695.52

    Interstitial High Alcohol Sensor for Steel Tanks

    The Interstitial Sensor for steel tanks with high alcohol product is made of stainless steel and detects the presence of liquid between the double walls of the tank. Constructed of non-corrosive stainless steel for monitoring of steel tank interstitial in high alcohol alternative fluids such as E85. The sensor triggers visual and audible alarm to notify you immediately of any leaks, so you take quick and efficient action to help prevent safety and environmental issues. The console can also trigger an on-site alarm for even greater warning capability.

    Add to cart
  • Veeder Root Interstitial Sensor for Steel Tanks

    $450.00$460.00

    Interstitial Sensor for Steel Tanks

    The Interstitial Sensor for steel tanks is non-discriminating and detects the presence of liquid between the double walls of the tank. Detect dangerous leaks in double-walled steel tanks. The presence of liquid in the interstitial space of double-walled tanks triggers an alarm in your automatic tank gauge console. The visual and audible alarm notifies you immediately of the problem, so you take quick and efficient action to help prevent safety and environmental issues. The console can also trigger an on-site alarm for even greater warning capability.

    View products
  • Veeder Root Non- Discriminating Piping Sump Sensor

    $251.16$266.80

    The Non-Discriminating Piping Sump Sensor is installed in a containment sump and will detect the presence of a liquid. Simply and reliably detect the presence of liquid in the containment sump with the Non-Discriminating Piping Sump Sensor. Receive an alarm with liquid is detected at a minimum of 1.84”.

    View products
  • Veeder Root Non-Discriminating Interstitial MicroSensor for Steel Tanks

    $750.00

    The non-discriminating small, easy to install solid-state MicroSensor is designed detect liquid in the interstitial space of a steel tank or a fill riser containment.

    Add to cart
  • Veeder Root Non-Discriminating Interstitial Sensor for Fiberglass Tanks

    $450.00

    Non-Discriminating Interstitial Sensor

    The Non-Discriminating Interstitial Sensor for double-wall fiberglass tanks detects the presence of liquid in the interstitial space of the tank. The Veeder-Root Interstitial Sensor detects the presence of liquid between the double wall of fiberglass tanks. Liquid triggers an alarm signal to your automatic tank gauge. You’ll know immediately where the problem is so you can take action to prevent serious and costly safety and environmental problems.

    Add to cart
  • Veeder Root Position Sensitive Interstitial Sensor for Steel Tanks

    $841.80

    The Position Sensitive Interstitial Sensor detects the presence of liquid in small containment areas of double wall steel tanks. In addition, it provides an alarm when the sensor is not positioned correctly on the bottom of the interstitial space.

    Add to cart
  • Veeder Root Single Point Hydrostatic Sensor

    $402.96

    The Single-Point Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a double wall storage tank. The Single-Point has one float and can be used in low groundwater locations. If an inner-wall leak occurs, the brine seeps into the tank triggering a fuel alarm, or if the outer wall leaks, the brine seeps out of the tank interstice triggering a fuel alarm. With our Single-Point Hydrostatic Sensors, if either an inner or outer leak occurs, the brine level decreases and a low-level alarm is triggered.

    Add to cart
  • Veeder Root Single-Point MINI-Hydrostatic Sensor

    $445.00

    Single-Point Mini-Hydrostatic Sensor

    The Single-Point Mini-Hydrostatic sensor accurately detects fluid level change in the interstice reservoir of a double-wall sump. If a leak occurs in the sump interstice, the brine seeps out of the reservoir triggering a low level alarm.

    Add to cart
  • Veeder Root Solid-State Alternative Ethanol Fluid Interstitial Sensor

    $750.00

    The interstitial sensor for double-wall fiberglass tanks with high alcohol product uses solid-state liquid level sensing technology to detect liquid in the interstitial space of the tank. It is approved for use with high alcohol alternative fluids such as E85. Prevent serious product loss, safety and environmental issues by quickly detecting any leaks in the interstitial spaces of fiberglass tanks.

    Add to cart
  • Veeder Root Solid-State Discriminating Interstitial Sensor

    $750.00

    The Discriminating Interstitial Sensor for double-wall fiberglass tanks uses solid-state liquid level sensing technology to detects the presence of, and differentiates between, hydrocarbons and other liquids in the interstitial space of the tank. Prevent serious product loss, safety and environmental issues by quickly detecting leaks in fiberglass tanks.

    Add to cart